#: locale=en
## Tour
### Description
### Title
tour.name = Cologix COL3
## Skin
### Multiline Text
HTMLText_09AB5263_AD96_9A05_41AB_5181DCF461D1.html =
HTMLText_0BB28F39_ACAF_AA05_41DE_4FA01169BC33.html =
HTMLText_0C843C36_AD95_AE0F_41C7_79DE4990D71E.html =
HTMLText_12415881_AC95_9605_41D8_2E40ED433085.html = Battery Monitoring
24/7/365 battery health monitoring allows Cologix to recognize a reduction of a battery's efficiency in advance of battery failure. This early detection allows impact free replacement of batteries, reducing maintenance windows and preventing downtime.
HTMLText_322C07B1_7959_3C45_41C4_866CD4857B1D.html =
HTMLText_3494C8E6_7959_15CE_41DB_F8D12A35510E.html =
HTMLText_3B4DAC51_ADF2_6E05_41E0_ABF127869B27.html = Cross Connect Pulley System
HTMLText_3E9F369B_AD93_9A05_41D4_B040C94FF221.html = CRAC Gallery Cooling System
This is one of the COL3 CRAC (Computer Room Air Conditioner) galleries. It offers 770 tons of cooling capacity per data center hall and houses VESDA (Very Early Smoke Detection Apparatus) fire detection systems. All three data center halls maintain a minimum of N+1 cooling.
HTMLText_528D9CB7_4AB6_096D_41C2_04015D8E6C34.html = Attention to Detail,
with Functional Design
Inside you will find a number of amenities to support you and your team, including a tech lounge, kitchen amenities, workstations, a conference room
and restrooms.
HTMLText_52F6FFB3_4A8E_0764_41BF_5CDA0074ADCE.html = Energy Efficient Raised Floors
24” raised floors to distribute cold air under all cabinets, requiring less energy.
HTMLText_53B1D4AB_4B8B_F964_41D2_4D336C1D2D67.html = DC03
Our data hall 3 offers 20K SQF, which is available for a custom build-out. The data center has 3MW of available critical infrastructure power and has dedicated A/B Generators and A/B UPS power distribution in private secured rooms. We have space ready for you.
Contact us today.
HTMLText_566EE3E4_76EB_1BC2_41B9_F3F1E8DE7A66.html = Fully Equipped Tech Lounge
Available seating with kitchen, microwave, vending machines, and a TV, available 24/7.
HTMLText_57DEF7FF_76EB_3BBE_41AD_F0DF134D2DB7.html = Conference Room
Available for onsite meetings by appointment.
HTMLText_5827FED9_4AFA_0924_41AD_83A790496011.html = Security Gate
Entrance and exit gates control all vehicle access to the campus.
HTMLText_58C676F6_4AFA_06EC_41CC_21087C78B054.html = Perimeter Fence
COL3 is surrounded by a 10 foot, K-rated perimeter fence which protects the critical IT infrastructure, and is able to withstand 15,000 lbs of force @ 30 mph.
HTMLText_59C2CFC6_7929_6BCE_41C6_33904202F5CF.html = Freight Elevator
A 7.5 ton Otis Freight elevator to access data center halls 3 and 4 as well as the roof.
HTMLText_5A7C3518_4A9E_1B24_41B4_CA684D1FEE62.html = 6 Levels of Security
1. K-Rated Fence Entrance
2. Front Entrance
3. Guard Desk/Man Trap
4. Circle Lock
5. Data Hall Mantrap
6. Cage Access
HTMLText_5B170996_4A8A_0B2F_41C2_8DDCE2FEABCF.html = We Protect Your Critical Infrastructure
Cologix offers five levels of security at every facility to protect your data. All visitors must pass through our five layers of physical security before gaining access to any customer cabinets, cages or suites. Additional survelliance and detection systems monitor entry and exit points.
HTMLText_5DE40C45_7929_2CCD_41BF_721FB9FDB147.html =
HTMLText_5ED214BE_7929_7DBF_41B2_3B30A1CCE146.html = Main Entrance
A Tier III certified facility, COL3 is built to weather any storm. Able to withstand an EF4 tornado, it offers reinforced concrete and precast panels which resist impact of up to 200 mph. Concurrently maintainable, it offers scalable power solutions and customized, flexible, hyper-secure solutions for hyperscale & enterprise customers.
HTMLText_6B12491A_7729_1447_41C2_80BF37181063.html = Backup Fueling
On-site fuel capacity for 72 hours run-time at full load with redundant 36,000-gallon tanks on-site, priority refueling from diverse suppliers & facility exemption from emergency power.
HTMLText_6B462AC1_4A96_15A6_41A8_E2EC95FDEAF2.html = VESDA Fire Detector System
Very Early Smoke Detection Apparatus.
HTMLText_6B4FD95E_773B_14FE_41D9_5AFCBD9A426C.html = Security Desk
Trained security personnel on duty 24/7/365 provide a manned, lobby security station as well as operate survellience systems and physically walk through the data center. As the single point for visitor clearance, the human security checkpoint is protected by bullet resistant glass and ballistic wall panels. Guards may issue badges to provide door access.
HTMLText_6B553054_772B_14C2_41D7_CB11D1DAAD33.html =
HTMLText_6B5AC91A_7727_3446_41DC_1A65BAAF282C.html = AC/DC Power Available
Cologix standard low voltage pathways and AC/DC power with 3 MW of critical infrastructure power available at an average density of 5 kW per cabinet. Data center PDUs are monitored down to the customer breaker or branch circuit.
HTMLText_6B83B282_773B_3447_41D8_1668F1B85B50.html =
HTMLText_6B886564_772B_1CC3_41CF_5BDFC3FF3922.html = Supporting Scalable Deployments,
Secured-Locking Cabinets
Space for smaller deployments and/or deployments not requiring a custom cage are available.
HTMLText_6BB32D3E_772B_ECBE_41D6_4CA14F37C015.html = Customer Staging Area
Customer burn-in area for customers to set up and configure equipment with a dedicated UPS to protect customers equipment prior to racking the equipment in their cabinet.
HTMLText_6BD621E2_7729_17C6_41B1_F67D11256BF4.html =
HTMLText_6BEE3D4F_7739_2CDE_417E_0B3D7F16EC33.html = Transformer System
13,200kVA stepdown transformer maintained by Cologix which allows us to be our own substation.
HTMLText_6C0460B3_7729_1445_41C0_BAF4DBD74008.html = Fire Suppression System
View of dual interlock, dry-pipe, pre-action fire system.
HTMLText_6C0B3579_7739_3CC2_41A6_24D91E5414C1.html =
HTMLText_6C23F6C3_7729_1DC6_41C0_04E0C4B86CAE.html = Shipping & Receiving
Security personnel can support shipping and receiving without leaving the security office.
HTMLText_6C2EC6CF_772B_3DDD_41A9_CBCC1EB0B9E5.html = Private Cages
With private cages and suites, customized security options are available.
HTMLText_6C495459_773F_3CC2_41B6_479C8E9FE55E.html = Flexible Workspace
COL3 also includes space for customers to work near deployments as well as access to local engineers and support teams.
HTMLText_6C5362F0_772F_35C3_41AF_19106E20D8AA.html =
HTMLText_6C7A098B_7739_1446_41DC_2BF22CF4B98C.html = Turnstile
The main circle lock provides access to all four data center halls. It is a single person, anti tailgating device and requires badge and biometrics to enter.
HTMLText_716B5B7C_68A1_20D2_41B0_D94A144F839C.html = Rooftop Courtyard Protects IT Infrastructure
Protected by a 200 mile an hour wind wall giving our exterior infrastructure the same protection as our internal assets, the rooftop courtyard includes important systems.
The roof system itself has no penetrations above the data halls and no external drains run above and/or under the data center floors. The roof was constructed with a white PVC membrane to prevent water penetration and prevents excess heat energy accumulation.
HTMLText_71A380F1_68A1_61D3_41D3_6A6C9DC862AA.html = Rooftop Grounding System
The grounding system consists of a grounding loop that encompasses the entire COL3 facility as well as eight 10’ grounding rods. The building ground system connects to the main grounding loop and is present in each data hall, electrical rooms, mechanical rooms and generator rooms.
HTMLText_7E388E45_68A7_2030_41D7_131D0C0E6639.html = Rooftop Heat Rejection System
The heat rejection system consists of 85 condensers which leverage a free cooling component to maximize efficiency. The condensers are stand-alone refrigerant systems for each CRAC unit.
HTMLText_7EE568D1_68A1_21D3_41D0_D8808A6085F9.html = Rooftop Lightning Protection System
The lightning protection system has been designed to NFPA standards and air discharge rods have been mounted to the exterior edges of the building parapets as well as select condensers in the
heat rejection courtyard.
HTMLText_8480133B_06C2_2F9F_41B7_6526A3B0C227.html = Welcome to the 360 virtual tour of Cologix’s COL3 facility.
To enable tour audio, please click the “Enable Audio” button in the top right corner after starting the tour.
HTMLText_8A745FF4_9065_A60B_41AC_D739D3C6C7E8.html = Thermal Imaging Cameras
for Monitoring & Safety
FLiR forward-looking infrared cameras allow monitoring and annual performance testing without operational interruptions.
HTMLText_9209E433_B9FB_A92B_41D1_F5F8BD957235.html = Meet-Me-Room Offers Unparalleled Network
and Service Provider Choice
COL3 offers connectivity to more than 50 network providers (including the Ohio-IX Internet Exchange) and over 20 cloud service providers, including direct access to Amazon Web Services via the AWS Direct Connect node, providing customers low-latency access to the AWS and Google US East 2 region.
As the interconnection core, we took extra precaution to make sure our customers are always connected and protected. The room consists of a secured A-side/B-side layout with biometric readers controlling access and HD video monitoring on all aisles. All of our carriers have independent and diverse paths to COL3 and the low voltage fiber and copper connectivity has been designed with completely redundant A/B paths from building entrance to each customer cabinet.
HTMLText_9229BD7A_BE2D_9B24_41B1_C06CA14F9D17.html = Loading Dock
1,500 lbs/SQF with dedicated, sunken loading deck. Additional restrooms provided for delivery personnel to protect COL3 facility access into hardened security spaces.
HTMLText_9271DB6A_B9E4_9F24_41C2_37F57349907B.html = We've Got You Covered
with Our Generator Bays
Capacity for 16, 2.5 MW Caterpillar generators. As with utility, generators are maintained in a 2N configuration. Generator rooms are separated with three-hour fire walls. Each generator has a “halo” system for sprinkler coverage.
HTMLText_97DEC6A9_90AF_661D_41E4_50788BED437B.html = Connected to Data Halls
Connect to your digital infrastructure while your staging with fiber connectivity to the data halls.
HTMLText_9A4F57D7_BA64_976B_41B0_FE34799DD8BD.html = Mantrap
Each data center hall has a separate mantrap entrance requiring dual authentication with a valid access card and corresponding fingerprint validation with 2-factor authentication. Dual interlocked, automatic doors.
HTMLText_9ABD4248_BA5B_A965_41E5_AF06CEA2B2C5.html = Most Connected, Flexible and Secured Campus
Between Ashburn and Chicago
COL3 is the largest, most connected network neutral data center with low latency and strong interconnection capabilities to build and scale your business. Cologix Access Marketplace offers a self-service portal to provision services on-demand, in minutes. This facility is the best option for enterprises to future-proof your businesses with a robust ecosystem of clouds, carriers and other network providers to support your digital transformation.
HTMLText_9ACE7154_BA3B_EB6D_41C1_DB245266D8CC.html = DC03
Our 20K SQF Data Center Hall 3 contains shared colocation with secured cabinets and custom cages.
HTMLText_9B1CB0DF_BA64_E91B_41E0_3581DCC3F9B4.html = Security Lobby
Within the Security Lobby, visitor identity must be verified with valid government-issued photo identification.
An intrusion detection system monitors all ingress/egress points throughout the facility, while on-premises security personnel physically monitor the facility.
HTMLText_9B599685_BA6C_A9EC_41D4_CC4AF9C1DC4A.html = COL3 - Central Ohio's Largest
Network Neutral Data Center
Within a 10-hour drive of 47% of the U.S. population and 29% of the Canadian population, COL3 sits at the convergence point of the long-haul fiber crossroads and the regional carrier fiber network.
This data center offers robust infrastructure with top connectivity to a wide range of network & cloud service providers. It provides up to 20 MW across 160K SQF in a highly scalable data center.
HTMLText_9CF444EA_B9E5_A925_41E3_48E4A3EE0FF1.html = Redundant Automatic Transfer Switch
COL3 has N+1 redundant configuration.
HTMLText_9D014ADD_B9FC_991F_41E6_9E87C69F4E88.html = Fire Detection and Suppression Systems
The Very Early Smoke Detection and Alarm (VESDA) system is used in conjunction with multi-zoned, dry-pipe, double-interlock and pre-action fire suppression systems which are also designed to alert on-site personnel to any incidents.
Fire detection and suppression systems are inspected and maintained on a scheduled basis in accordance
with local standards.
HTMLText_9D4C41DF_B9E4_AB1C_41D8_DD74077B2A0E.html = Uninterruptible Power Supply (UPS)
Our data centers are engineered to deliver uninterruptible power even in the event of multiple component failures, providing our customers with a 100% uptime
service level agreement.
HTMLText_9D4E65E3_B9FC_AB2B_41DE_8EC4C123302E.html = Video Surveillance
167 security camera feeds are monitored 24X7 with 90-day HD backup, providing full interior & exterior coverage.
HTMLText_9D557750_B9FD_B765_41CE_946D7491E5A6.html = Electrical Power Room
2N configuration, A/B electrical distribution rooms
separated by fire-proof walls.
HTMLText_9DE9D9DB_BA5D_7B64_41D5_D9ADF419E344.html = Biometric Reader
Access to COL3 is controlled by a 2-factor authenication system with key card
and biometric readers.
HTMLText_9E37D6AB_B9DC_A924_41C2_28F50AB14F27.html = Customer Storage
Storage area for long or short term
secure storage needs.
HTMLText_9F8715E4_B9E5_6B2D_41D9_260CCF474A5D.html = Demarcation Panel
Demarcation points allow Equinix to deliver interconnection to the cage, providing each customer full control over their connections.
HTMLText_E435342C_F588_1C10_41CD_2860E8E5B2EA.html = Fire Suppression Cylinder
### Label
Label_5D4D02AA_69A7_FC04_41CE_A216954D1332.text = COL3
### Tooltip
IconButton_01428965_4AB6_7769_41D2_A5298AE81791.toolTip = Mute/Unmute Audio
IconButton_40D1CF05_5278_5B71_41CC_0013BFADF3D9.toolTip = Toggle Gallery
IconButton_4119B4DD_5188_2E91_41B4_DB380EBC26F2.toolTip = Look Down
IconButton_416A0EAA_6BA1_6071_41CC_18E9F53CE3B6.toolTip = Pause/Play Audio
IconButton_4185A425_5278_2DB1_41C3_641F043D200A.toolTip = Toggle Fullscreen
IconButton_41E822ED_5388_EE8B_41CD_EB27B81427B2.toolTip = Next Panorama
IconButton_41E842ED_5388_EE8B_41B7_EA16C2B0C826.toolTip = Look Right
IconButton_41E8C2ED_5388_EE8B_41C0_06430D6A3CE9.toolTip = Zoom In
IconButton_41E922E7_5388_EE87_4179_B2F38AB79A39.toolTip = Restart Audio
IconButton_41E942E7_5388_EE87_41C9_BDCA41DE74FD.toolTip = Zoom Out
IconButton_41E992ED_5388_EE8B_41CD_4C69F9CCA85C.toolTip = Look Up
IconButton_41E9E2E8_5388_EE89_41CC_948883A3BE45.toolTip = Look Left
IconButton_42EB111E_5288_2B89_41D4_AB07275D9789.toolTip = Previous Panorama
Image_4C29BA57_FA27_64A6_41C2_8C6128036ABD.toolTip = Forward
Image_7CBECF07_FA27_9CA7_41D6_2E3CA7A24B44.toolTip = Backward
## Media
### Title
map_0CD42BBB_55F6_0BDA_41A7_54460CF0CFB5.label = COL3 FloorPlan 1
map_0E30677E_55FB_FB5A_41CA_93660E651406.label = COL3 FloorPlan 2
panorama_50B7B730_4B96_0763_41B1_9C139E193C3E.label = Security Lobby
panorama_5180264E_7929_1CDE_41DD_3FD8DE72F0A6.label = Burn-in Room
panorama_518193E6_7929_3BCC_41B0_13428A93CF20.label = Private Cage
panorama_518243A7_7929_144D_41C9_D3705913CAAD.label = Loading Dock
panorama_518BF5D4_7929_3FC3_41D6_82FA6495F5A7.label = Underground Fuel System
panorama_51927C76_792F_6CCF_41C3_2E75CBF1FAFB.label = Security Entrance noMask
panorama_5193EAFF_7938_F5BD_41A8_0C2765BA39A3.label = Amenities
panorama_5196EF65_7929_6CC2_41A2_12751E846729.label = Secured Cabinet Spaces
panorama_51981314_7939_F442_41D6_05CF7449DE78.label = Exterior
panorama_5198418A_792B_F447_41D1_1A4FA0878459.label = Electrical Room 2
panorama_5198D337_7929_F44D_41CE_F225175966EE.label = Private Cage
panorama_519A4D8F_7928_EC5D_41A3_C9E38D8279F2.label = Generator Bay
panorama_519B5787_792B_3C4E_41C6_2BB26D08927F.label = Electrical Room
panorama_519B7514_7927_3C43_41D8_B2CF5D5324DC.label = Kitchen
panorama_519B80A6_792B_344E_41D5_C97CC33036BA.label = Switchgear Room
panorama_519C5118_792F_1443_41DC_E7385ED496A0.label = CRAC Gallery 2
panorama_519CF001_792B_3445_41B4_2E89D80A0E4B.label = Transformer System
panorama_519DA58D_7929_3C42_41D9_8E29D6BE4972.label = Colocation Floor C
panorama_519E47EE_7929_1BDE_41D2_5D002B671851.label = Customer Storage
panorama_519E9BC2_792B_6BC7_41D2_5FE80631492E.label = Deionized Water Supply
panorama_519EEA52_7939_34C6_41CF_77570C7D63BE.label = Security Lobby 2
panorama_519F0C78_792F_2CC3_41D3_862A62565430.label = Security Lobby noMask
panorama_519F6409_792F_1C42_41AB_2EF5AE6269E7.label = Power Room 2
panorama_519F9C1A_7929_2C47_41D8_D63B3CB54098.label = Colocation Floor A
panorama_519FF302_7929_1447_41D5_A1ECF4C04874.label = Freight Elevator
panorama_51A14D4C_7928_ECC2_41A0_0868803F408D.label = Data Center Hall
panorama_51A3DA38_7927_7443_41B9_D06A41EC6B5F.label = ManTrap
panorama_51A7A8E5_7927_35C2_41AD_1A17214B0B24.label = Flexible Workspace
panorama_51A98D98_7939_2C42_41AA_0727D0AC7C72.label = Security Entrance
panorama_51AAC758_7929_7CC2_41D0_9772117AB366.label = Colocation Floor B
panorama_51B34568_792B_7CC2_41BA_709486EFB445.label = Switchboard
panorama_51B6B777_7929_1CCE_41DA_917A24FA3CD6.label = Roof
panorama_51BB8BB2_792B_3446_41B9_B43EA9E47E59.label = Fire Suppression System
panorama_51BC1AA8_7928_F442_41CE_B8FCAED8E57D.label = CRAC Gallery
panorama_51BC55A5_7927_1C42_41A9_C67CDA6FCB70.label = Conference Room
panorama_51DFBCF3_7929_2DC6_41CA_69F1A4C573A8.label = Exterior Hallway
panorama_54DFC831_7939_3442_4173_A62A1BDE0D59.label = Security Gate
panorama_89A4E8E4_909F_6A14_419B_F64C94660E51.label = Meet-Me-Room
panorama_8F090536_919C_BA77_41D4_4F100FF3FC4C.label = Restrooms